The Casimir effect: how do you measure a force in a vacuum?

Steven K. Lamoreaux’s experiment measures a force between a conducting sphere and a plate, separated by 0.6 to 6 micrometres. It tests Casimir’s prediction without measuring available energy.

Add LetzView to my preferred sources
Workstations and instruments in a laboratory
Image source and licence
Ludovic Delot, Pexels, Licence Pexels

How do you measure a force in a vacuum, where nothing seems able to push or pull? An experiment published by physicist Steven K. Lamoreaux in 1997 offers a concrete answer: bring a conducting sphere close to a conducting plate, then measure the very small force linking them. Under the conditions studied, the result agrees with the prediction of the Casimir effect to within about 5%.

The subject was discussed on Saturday on “Vacuum energy”, on France Inter, with physicists Pierre Brun and Paul Indelicato. Lamoreaux’s published apparatus helps clarify the concrete meaning of the word “energy” in this debate.

The vacuum is not an absence of phenomena

In 1948, Dutch physicist Hendrik Casimir predicted that a force could arise between two very close conducting surfaces. The explanation rests on the way these surfaces modify fluctuations in the electromagnetic field associated with the vacuum. The possible fluctuations between the conductors are not the same as those outside them. This difference translates into a stress, and therefore into a measurable force.

This description should be distinguished from an image sometimes invoked too hastily: the vacuum does not behave like an ordinary reservoir from which one could draw available energy. Lamoreaux’s experiment measures a force between two objects. It does not demonstrate that usable energy can be extracted from it.

The original prediction concerns two nearby, flat conducting plates. But verifying such a weak force requires being able to measure the movement of an apparatus with great precision and to separate the effect being sought from other interactions that might disturb the measurement.

A sphere facing a plate, not two plates

Lamoreaux’s experiment does not use two parallel flat surfaces. It places a conducting sphere opposite a flat plate. The distance between them is explored over a range from 0.6 to 6 micrometres, or millionths of a metre. This geometry matters: it describes the apparatus actually used, and should not be confused with the theoretical configuration of two flat plates.

To detect the force, the team uses an electromechanical system fitted with a torsion pendulum. Put simply, a force that tends to turn the apparatus produces a measurable twist. This principle turns a tiny interaction into a mechanical displacement that the instrument can track.

But the signal does not come labelled with its origin. Residual electrostatic effects can also contribute to the observed force. Lamoreaux describes electrical measurements and a fitting procedure intended to distinguish these contributions from the Casimir effect. The challenge, then, is not just to detect an interaction, but to determine whether its variation with distance matches the prediction being tested.

What agreement to within 5% means

Lamoreaux reports agreement with the theory at the 5% level. This figure describes the agreement obtained between measurement and theory in the analysis presented; it does not mean that every possible situation was tested to this degree. The result applies to the apparatus, distances and analysis described in his paper.

One detail is worth bearing in mind: in his precise fitting procedure, measurements taken at less than 2 micrometres are omitted, as the paper’s text makes clear. The range stated in the title remains 0.6 to 6 micrometres, but not all the points within this range therefore contribute in the same way to the fitting procedure presented. This distinction between the measurement range and the range included in a fit is essential to reading the result correctly.

The experiment does not directly observe vacuum fluctuations. It measures a force between conductors, then compares the data with a theoretical prediction while accounting for competing interactions. This is a familiar distinction in physics: the observation concerns a measurable signal; the interpretation links that signal to a model and to assumptions about the apparatus.

An experimental test, not an energy source

The experiment’s significance lies in this confrontation between a theoretical idea and a delicate measurement. Casimir’s prediction is not merely a calculation: a force compatible with it is observed in a specific experimental configuration. That does not, however, turn the phenomenon into a way of producing energy, nor does it allow a direct explanation of another physical phenomenon to be inferred from it.

In particular, the result described here is not a cosmological measurement and does not allow the Casimir effect to be identified with dark energy with certainty. These are separate questions, requiring their own models and observations. To understand what the experiment shows, the firm conclusion is more limited: at the micrometre scale, two conductors under precise conditions exert a force whose measurement is compatible, to the degree reported by the physicist, with Casimir’s prediction.